Skip to main content Skip to footer accreditations
  • Made in North Devon since 1973
  • BSI Kitemark ready-mixed concrete
  • Manufactured to BS EN 14992
  • UK-wide & European delivery

Civils · agricultural · bulk storage

Retaining Walls.

Engineered to Eurocode 2. Lifted in by lunchtime.

What's the difference between a retaining wall and a king post wall?

What's the difference between a retaining wall and a king post wall? "Retaining wall" is the family — any structure holding back earth. A king post wall is one type, with steel UC posts in piles and precast infill panels. Cantilever, L-block and gravity walls are other types in the same family. WCCP supplies all four.

Precast retaining walls 1.0m to 6.0m high (3'3" to 19'8"), designed to BS EN 1992-1-1 (Eurocode 2). King-post systems handle up to 60 kN/m² surcharge, cantilever 50 kN/m², L-block 30 kN/m², panel-and-post 40 kN/m². Foundations vary by system. Lead time 2-6 weeks; bespoke heights and 120-year design lives priced individually. Includes the named WCCP Rapid Fit Retaining Wall System.

  • · Heights 1m–6m (3'3"–19'8")
  • · Up to 60 kN/m²
  • · Eurocode 2 design
  • · 50-year design life
  • · Four systems
  • · 2–6 week lead
Precast concrete L and T retaining walls on farm — West Country Concrete Products, Devon

Pick a system

Four ways to retain ground.

Same yard, same paperwork — different shapes for different jobs. Click through to the system page for full specs.

Named system

Rapid Fit Retaining Wall System™

WCCP's named retaining-wall system. A 900 × 1500mm (2'11" × 4'11") face on a 1200mm (3'11") depth at 2,120kg (4,670 lb) per unit, with 'L' shaped top units available at 885kg (1,950 lb).

The unit shape permits both convex and concave wall faces — a single system cope with curved retention runs, civils retention bends and the gentle sweeps that L-blocks and cantilever panels can't follow. Engineered to BS EN 1992-1-1 with 50-year design life.

Specification

  • ·Face: 900 × 1500mm (2ft11in × 4ft11in)
  • ·Depth: 1200mm (3ft11in)
  • ·Weight: 2,120 kg per unit (4,670 lb)
  • ·'L' shaped top units available at 885 kg (1,950 lb)
  • ·Shape permits convex and concave wall faces
  • ·Engineered to BS EN 1992-1-1 (Eurocode 2)

Wall types

Wall types.

Free-standing precast concrete A-wall retaining unit cast by West Country Concrete Products, Devon
A-wall (free-standing)
Installed precast concrete king-post retaining wall with steel posts and panel infill on a UK site by WCCP Devon
King-post wall installed

Specification at a glance

Heights, surcharge and foundations.

Indicative ratings across the four systems. Site-specific design always carried out to BS EN 1992-1-1.

System Height range Max surcharge Foundation Typical use
King Post 1.0–6.0m (3ft3in–19ft8in) Up to 60 kN/m² Strip + post pockets Civils, road schemes, basement props
L-Block 1.0–6.0m (3ft3in–19ft8in) Up to 30 kN/m² Compacted hardcore Silage, grain, aggregate, biomass bays
Cantilever 1.5–6.0m (4ft11in–19ft8in) Up to 50 kN/m² Cast-in-situ heel Free-standing civils retention
Panel + post 1.0–4.5m (3ft3in–14ft9in) Up to 40 kN/m² Strip + UB/UC posts Boundary walls, push walls

Where they go

Common applications.

From a 60-cow silage clamp to a 6m (19'8") highway retention scheme — same range, sized for the loading.

  • ·Highway and rail civils retention up to 6m
  • ·Silage clamp side and end walls — agricultural
  • ·Bulk-storage bay divisions for grain, biomass, aggregate
  • ·Slurry and effluent containment with sulphate-resisting mix
  • ·Residential and commercial level-change retention
  • ·Flood-defence and bund walls for fuel and process plant
  • ·Reinforced earth retaining for embankments

Standards & certification

Engineered to current code.

BS EN 1992-1-1 (Eurocode 2)
Structural design of concrete — every wall calculated by our in-house design team.
BS EN 14992
Precast wall elements — manufactured under factory production control.
BS 8500-1:2023
Concrete spec — designated mixes including DC-3 / DC-4 for aggressive ground.
BS EN 13369
Common rules for precast — factory production control framework.
BS 5502-22:2003
Agricultural buildings and structures — for farm retention applications.

Configure your retaining wall

Send section, height and surcharge — we will spec the cheapest right answer.

Related products

Often ordered alongside.

View full range

Common questions

What people ask about retaining walls.

Five questions we answer most weeks. If yours is not here, ring the yard.

Which retaining system do I want? +

For agricultural bay storage, L-blocks every time — quick to set, no footing. For civils retention up to 6m with surcharge, king post is usually the cheapest. For free-standing engineered retention to road or rail loadings, cantilever. We will design the cheapest right answer for your loadings — send us the section and we will spec it.

What heights can you go to? +

All three systems run from 1m (3ft 3in) up to 6m (19ft 8in) as catalogue. Above 6m we get into bespoke engineering and tied-back solutions — talk to the yard.

What surcharge ratings do you support? +

Up to 60 kN/m² on king-post systems with the right post and footing, 50 kN/m² on cantilever, 30 kN/m² on free-standing L-blocks. Site-specific design always to BS EN 1992-1-1.

Do you do the install? +

King post and cantilever installs we project-manage end to end. L-blocks are designed for the customer's teleporter or loader. We supply the install drawing, the bedding spec and the lift points either way.

How are designs signed off? +

Every wall is designed to BS EN 1992-1-1 (Eurocode 2) and manufactured to BS EN 14992 / BS EN 13369, with a designer's sign-off; structural calcs and conformity documentation are available on request. For grant-funded jobs we supply the SSAFO 2018 paperwork too where slurry contact is involved.

Spec sheets

Download the technical data.

A-Wall, L-and-T-Wall and Rapid-Fit retaining block PDFs — the geometry your engineer needs.

How would you like it?

Supply-only or fitted — Retaining Walls

Supply only

Per-unit / per-metre supply

Lead time: 3–5 weeks

  • Designer-stamped drawings to BS EN 1992
  • Panels, posts or L-blocks per the system
  • BS EN 14992 / BS EN 13369 documentation
  • Delivery on our HIAB to your site
  • Strip-footing groundworks and excavation
  • On-site setting / fixing labour
  • Backfill, drainage and granular materials

priced individually. Send the section drawing and we will spec the cheapest right answer.

BIM-ready packs

Retaining walls — engineer pack.

Direct downloads where available, with the rest sent direct from engineering on request. All packs versioned to BS EN 14992 / BS 5502-22 where applicable.

Need something else, or a stamped drawing? Email engineering@wccp.co.uk — typical reply within 24 working hours.

Ready to spec it?

Send us a section, the height and the surcharge. Quote and lead-time same day.

Call WhatsApp Quote