- Made in North Devon since 1973
- BSI Kitemark ready-mixed concrete
- Manufactured to applicable British Standards
- UK-wide & European delivery
Civils · agricultural · slurry
Prestressed Wall Panels.
20ft stocked lengths. Zero formwork on site.
Prestressed precast wall panels are manufactured in six stocked thicknesses, from 95 mm (4in) up to 280 mm (11in), with cast-in lifting anchors. WCCP panels are stocked up to 6.096 m (20ft) and arrive ready to lift on the same lorry.
Prestressed concrete wall panels stocked in 95mm, 120mm, 145mm, 180mm, 230mm and 280mm thicknesses and 500mm to 1500mm widths (five stocked widths), cast in C40/50 sulphate-resisting concrete. Slim-profile — suits agricultural, civils and AD-plant builds. Stocked in 15ft (4572mm) and 20ft (6096mm) lengths, custom to 6500mm; 180mm (7in) panels can stand vertically in cantilever without posts, to the retained height your engineer specifies. Bespoke pocket details and exposed-aggregate finishes to specification.
- · Manufactured to applicable British Standards
- · Eurocode 2 design
- · Widths 500mm–1500mm (1'8"–4'11")
- · 95–280mm, 6 thicknesses
Specification
Stocked lengths, widths and thicknesses.
Panels are ordered by combining a length, a width (the panel's installed height) and a thickness from the three stocked lists below. Weight varies by combination and is confirmed at quote stage. Bespoke combinations — cut-outs, pockets, kicker details, exposed-aggregate finishes — quoted on application.
15ft and 20ft are standard stocked lengths. Custom lengths to 6500mm to order — site-specific design carried out to Eurocode 2.
Optional extras
- ·Double stressed to accept loading from both sides
- ·Bolts and brackets to fix panels to steel posts
- ·Mastic for sealing panels
- ·Panel rebates (to allow flush fitting)
- ·Lifting clutch that fits the cast-in panel rebate
Named system
Vertical Cantilever Panels.
Stand a 180mm prestressed panel vertically and cantilever it from the slab — no king post, no tie-back, no rear bracing. We supply the cantilever run to your engineer's section; your groundworker sets it. The panel does the work.
| Panel | Retained material | Maximum retained height |
|---|---|---|
| 180mm (7in) | Slurry | To your engineer's design |
| 180mm (7in) | Silage (with vehicle surcharge) | To your engineer's design |
| 180mm (7in) | Earth | To your engineer's design |
| 145mm (6in) | Slurry / silage / earth | To your engineer's design |
No supporting posts required.
Handling
Handling & install detail.
Where they go
Common applications.
One panel system, many jobs. From the dairy slurry store to the civils retaining wall on a road scheme — same factory, same paperwork, same yard.
- · SSAFO 2018-compliant slurry stores up to 6.0m wall height
- · Silage clamp walls — push-off ends, transition bays, ramp returns
- · Grain stores and bulk-aggregate bay divisions
- · L-block alternative on cantilever retaining walls
- · Bunds for fuel tanks, transformers and process plant
- · Push walls for waste-transfer and recycling sites
- · Boundary and security walls — exposed-aggregate finishes available
Standards & references
Cast to current British and European standards.
- British Standards
- Our products are manufactured in compliance with applicable British Standards. For information regarding the specific standards applicable to a particular product, please contact us.
- Eurocode 2
- Design of concrete structures. The code our precast elements are manufactured to.
- SSAFO 2018
- For agricultural slurry use — capacity statement supplied with every store.
Configure your panel run
Tell us thickness, height and run length — we will quote it.
Common questions
What do buyers ask about prestressed panels?
What thicknesses are prestressed panels available in?
Prestressed wall panels are stocked in six thicknesses (95, 120, 145, 180, 230 and 280mm), five widths from 500mm to 1500mm (the panel's installed height) and two lengths, 15ft (4572mm) and 20ft (6096mm). Custom lengths to 6500mm and bespoke details are cast to order.
What's the difference between prestressed and reinforced?
Reinforced concrete uses passive steel bars to handle tension. Prestressed concrete uses high-tensile strands tensioned before the concrete cures, putting the panel into permanent compression. The result: thinner, stronger, longer-spanning panels with far better crack resistance — particularly important for slurry and silage applications.
What concrete grade do you use?
Standard mix is C40/50 sulphate-resisting with CEM III/A cement (around 50% GGBS) for slurry and cubicles, with silage clamp walls at C50/60 sulphate-resisting, cast with a DC-3 or DC-4 designation where the ground or exposure class calls for it. Lightly reinforced items such as padstones use C40/50 (50 N/mm² at 28 days, CEM I); prestressed panels and robot bases use C50/60 high-strength. A C40/50 low-carbon mix with CEM III/B (around 70% GGBS) is available for retaining walls. Bespoke mixes available on request.
Are your products fire-rated?
Concrete is non-combustible — as a material it is classified Euroclass A1 without further testing. Fire-resistance performance (the REI classification) is not a property of concrete in general: it depends on the individual unit's thickness, axis distance to the reinforcement, support conditions and load level. Tell us the fire rating your building control or insurer requires and we will confirm the panel specification needed to meet it.
Can panels be painted, rendered or clad?
Yes — concrete takes paint, render, timber cladding or stone facing readily. We can supply panels with a smooth as-cast finish, a textured finish, or pre-drilled fixings for cladding battens. Specify at order.
How are products craned into place?
Panels are supplied with cast-in lifting anchors (Halfen-style). Units are delivered by artic or rigid lorry — on site you'll need a telehandler, forklift or crane to unload and position panels, depending on weight.
Related products
Often ordered alongside.
Specification sheets
Download the technical data.
Panel range overview plus the on-site handling, lifting and storage guidelines.
Drawings and specification sheets
Prestressed wall panels — engineer pack.
Direct downloads where available, with the rest sent direct from engineering on request. Our products are manufactured in compliance with applicable British Standards — contact us for the specific standards applicable to a particular product.
-
Prestressed wall panels: AutoCAD .dwg
RequestPlan, section and elevation — 2D drawings.
-
Prestressed wall panels: PDF specification sheet .pdf
RequestSpecifications, loadings, certification references.
Need something else? Email info@westcountryconcreteproducts.co.uk and the office will send it over.
Ready to specify it?
Send us heights, run length and the surcharge. We will come back with a quote and a lead time.
Page last updated: